Solar Power Plant

Solar low Voltage Power Plant

Applications – Commercial, Industry,
and Government

Smart Portable Solar
Solar Power Plant (SPP)

Looking for immediate, reliable solution for your remote, low wattage power requirements? SPP allow cost-effective alternative to pulling traditional AC power. Reliably power your equipment via direct 12 / 24 / 48 vDC or non-typical vDC, Power over Ethernet (POE).

Model Numbers
Available Output Voltages
12Vdc 24Vdc 48Vdc PoE
GN-SPP12140-311-E X
GN-SPP12140-311-E T1 X X X
GN-SPP12140-312-E X
GN-SPP12140-312-E DS3 X X X
GN-SPP12280-312-E X
GN-SPP12280-312-E DS3 X X X
GN-SPP12280-312-1 DS3 X X X
GN-SPP12560-314-4  X X X
GN-SPP12560-314-E  X X X
GN-SPP24280-312-E  X X X

Product Specifications

When you purchase our product, you get professional support.
Full time support team taking care of your requests, usually answering in less than 24h.

Solar Power Plant Hardware 

Solar-Power-Plant-1 SPP12560-316-4
Model Numbers and Technical Specifications

GN-SPP12140-311-E – Technical Specifications

Solar Array

  • Minimum 140 Watts Power Max
  • Minimum 17.0 Volts Power Max
  • Wired Nominal 12 Vdc
  • Prewired with Locking Plug-in Connectors
  • Size 26.3 x 59.1 inches (L x W)

Solar Mount

  • Side of Pole with High Wind Brace
  • Adjustable from 30 to 60 Degrees
  • Heavy Duty Aluminum with Stainless Steel Hardware

Enclosure

  • 25 x 16 x 15 inches (H x W x D)
  • Heavy Duty White Powder-Coated Aluminum
  • Built to NEMA 3R Standards
  • Pole or Wall Mounting
  • Stainless Steel Locking, Adjustable Hasps
  • Stainless Steel Hinge
  • Convection Cooling
  • Cable Access Glands Located at Bottom of Enclosure
Electronics

  • Charge Controller
    • Multi-Stage, Temperature Compensated
    • -40c to 60c Operating Temperature
    • PV Protection: Overload, Short Circuit, High Voltage
    • Load Protection: Overload, Short Circuit
    • Reverse Polarity: PV, Battery, Load
    • Transient Surge Protection
  • Fused, Nominal 12 Vdc Output
  • Hydraulic-Magnetic DC Circuit Breakers for PV & Battery
  • All Components Prewired
  • Heavy Duty Aluminum Enclosure Backplane with Earth Ground

Battery Array

  • Minimum 112 Amps (100AHr)
  • Battery Array Wired Nominal 12 Vdc
  • Sealed GEL VRLA

All Wiring Provided with Connectors Attached

GN-SPP12140-312-1 – Technical Specifications

Solar Array

  • Minimum 140 Watts Power Max
  • Minimum 17.0 Volts Power Max
  • Wired Nominal 12 Vdc
  • Prewired with Locking Plug-in Connectors
  • Size 26.3 x 59.1 inches (L x W)

Solar Mount

  • Side of Pole with High Wind Brace
  • Adjustable from 30 to 60 Degrees
  • Heavy Duty Aluminum with Stainless Steel Hardware

Enclosure

  • 27 x 17.25 x 17.5 inches (H x W x D)
  • Heavy Duty White Powder-Coated Aluminum
  • Pole or Wall Mounting
  • Stainless Steel Locking, Adjustable Hasps
  • Stainless Steel Hinge
  • Convection Cooling Shelf
Electronics

  • Charge Controller
    • Multi-Stage, Temperature Compensated
    • -40c to 60c Operating Temperature
    • PV Protection: Overload, Short Circuit, High Voltage
    • Load Protection: Overload, Short Circuit
    • Reverse Polarity: PV, Battery, Load
    • Transient Surge Protection
  • Fused, Nominal 12 Vdc Output
  • Hydraulic-Magnetic DC Circuit Breakers for PV & Battery
  • All Components Prewired
  • Heavy Duty Aluminum Enclosure Backplane with Earth Ground

Battery Array

  • Minimum 112 Amps (100AHr)
  • Battery Array Wired Nominal 12 Vdc
  • Sealed GEL VRLA

All Wiring Provided with Connectors Attached

GN-SPP12280-312-E  –  Technical Specifications

Solar Array

  • 280 Watts Power Max
  • Minimum 17.0 Volts Power Max
  • Nominal 12 Vdc
  • Prewired with Locking Plug-in Connectors
  • Size 52.6 x 59.1 inches (L x W)

Solar Mount

  • Side of Pole with High Wind Brace
  • Adjustable from 30 to 60 Degrees
  • Heavy Duty Aluminum with Stainless Steel Hardware

Enclosure

  • 25 x 16 x 15 inches (H x W x D)
  • Heavy Duty White Powder-Coated Aluminum
  • Pole or Wall Mounting
  • Stainless Steel Locking, Adjustable Hasps
  • Stainless Steel Hinge
  • Convection Cooling

Cable Access Glands Located at Bottom of Enclosure

Electronics

  • Charge Controller
    • Multi-Stage, Temperature Compensated
    • -40c to 60c Operating Temperature
    • PV Protection: Overload, Short Circuit, High Voltage
    • Load Protection: Overload, Short Circuit
    • Reverse Polarity: PV, Battery, Load
    • Transient Surge Protection
  • Fused, Nominal 12 Vdc Output
  • Hydraulic-Magnetic DC Circuit Breakers for PV and Battery
  • All Components Prewired
  • Heavy Duty Aluminum Enclosure Backplane with Earth Ground

Battery Array

  • 224 Amps (100AHr)
  • Battery Array Wired Nominal 12 Vdc
  • Sealed GEL VRLA

All Wiring Provided with Connectors Attached

GN-SPP12560-314-4  –  Technical Specifications

Solar Array

  • Minimum 560 Watts Power Max
  • Minimum 17.0 Volts Power Max
  • Wired Nominal 12 Vdc
  • Prewired with Locking Plug-in Connectors
  • Size 105.2 x 60.5 inches (L x W)

Solar Mount

  • Side of Pole with High Wind Brace
  • Adjustable from 30 to 60 Degrees
  • Heavy Duty Aluminum with Stainless Steel Hardware

Enclosure

  • 58 x 21.625 x 18.0 inches (H x W x D)
  • Heavy Duty White Powder-Coated Aluminum
  • NEMA 3R compliant
  • Pole, Wall, or Pedestal Mounting
  • Stainless Steel Locking, Adjustable Hasps
  • Continuous Stainless Steel Hinge
  • Continuous Weld
  • Heavy Duty Storage Shelf
  • Convection Cooling

Cable Access Glands Located at Bottom of Enclosure

Electronics

  • Charge Controller
    • Multi-Stage, Temperature Compensated Charging
    • -40c to 60c Operating Temperature
    • PV Protection: Overload, Short Circuit, High Voltage
    • Load Protection: Overload, Short Circuit
    • Reverse Polarity: PV, Battery, Load
    • Transient Surge Protection
  • Fused, Nominal 12 Vdc Output
  • Hydraulic-Magnetic DC Circuit Breakers for PV and Battery
  • All Components Prewired
  • Heavy Duty Aluminum Enclosure Backplane with Earth Ground

Battery Array

  • Minimum 448 Amps (100AHr)
  • Battery Array Wired Nominal 12 Vdc
  • Sealed GEL VRLA
  • All Wiring Provided with Connectors Attached

Options

  • White Powder-Coat Stainless Steel NEMA 4X compliant   

GN-SPP12560-314-E  –  Technical Specifications

 Solar Array

  • 560 Watts Power Max
  • Minimum 17.0 Volts Power Max
  • Wired Nominal 12 Vdc
  • Prewired with Locking Plug-in Connectors
  • Size 105.2 x 60.5 inches (L x W)

Solar Mount

  • Side of Pole with High Wind Brace
  • Adjustable from 30 to 60 Degrees
  • Heavy Duty Aluminum with Stainless Steel Hardware

Enclosure

  • 58 x 21.625 x 18.0 inches (H x W x D)
  • Heavy Duty White Powder-Coated Aluminum
  • Pole, Wall, or Pedestal Mounting
  • Stainless Steel Locking, Adjustable Hasps
  • Continuous Stainless Steel Hinge
  • Continuous Weld
  • Heavy Duty Storage Shelf
  • Convection Cooling

Cable Access Glands Located at Bottom of Enclosure

Electronics

  • Charge Controller
    • Multi-Stage, Temperature Compensated Charging
    • -40c to 60c Operating Temperature
    • PV Protection: Overload, Short Circuit, High Voltage
    • Load Protection: Overload, Short Circuit
    • Reverse Polarity: PV, Battery, Load
    • Transient Surge Protection
  • Fused, Nominal 12 Vdc Output
  • Hydraulic-Magnetic DC Circuit Breakers for PV and Battery
  • All Components Prewired
  • Heavy Duty Aluminum Enclosure Backplane with Earth Ground

Battery Array

  • 672 Amps (100AHr)
  • Battery Array Wired Nominal 12 Vdc
  • Sealed GEL VRLA

All Wiring Provided with Connectors Attached

GN-SPP24280-312-E  –  Technical Specifications

Solar Array

  • Minimum 280 Watts Power Max
  • Minimum 17.0 Volts Power Max
  • Wired Nominal 24 VDC
  • Prewired with Locking Plug-in Connectors
  • Size 52.6 x 59.1 inches (L x W)

Solar Mount

  • Side of Pole with High Wind Brace
  • Adjustable from 30 to 60 Degrees
  • Heavy Duty Aluminum with Stainless Steel Hardware

Enclosure

  • 25 x 16 x 15 inches (H x W x D)
  • Heavy Duty White Powder-Coated Aluminum
  • Pole or Wall Mounting
  • Stainless Steel Locking, Adjustable Hasps
  • Stainless Steel Hinge
  • Convection Cooling

Cable Access Glands Located at Bottom of Enclosure

 Electronics

  • Charge Controller
    • Multi-Stage, Temperature Compensated
    • -40c to 60c Operating Temperature
    • PV Protection: Overload, Short Circuit, High Voltage
    • Load Protection: Overload, Short Circuit
    • Reverse Polarity: PV, Battery, Load
    • Transient Surge Protection
  • Fused, Nominal 24VDC Output
  • Hydraulic-Magnetic DC Circuit Breakers for PV and Battery
  • All Components Prewired
  • Heavy Duty Aluminum Enclosure Backplane with Earth Ground

Battery Array

  • Minimum 224 Amps (100AHr 12VDC)
  • Battery Array Wired Nominal 24VDC
  • Sealed GEL VRLA

All Wiring Provided with Connectors Attached