With advance micro grid technology and design, the water heater delivers upto 100% of annual hot water needs and save up to 30% or more energy cost.
Take a Look USA Made Technology
Applications: Industry, Commercial, & Residence
World class USA Made Technology
Green Notions Smart Hybrid Solar Water Heaters are engineered, and manufactured in USA by Sun Bandit® and Green Notions represents Sun Bandit® in Florida and Caribbean. Sun Bandit® Hybrid Water Heaters are a revolutionary new way in which solar is used to heat water by utilizing state-of-the-art PV technology. They are the toughest, reliable, durable, high performance, and easy to install water heater available in the marketplace. Green Notions and Sun Bandit® recognize the demand for high quality industrial and residential water heater at an affordable price. Call us today at 407-782-7371 and give us an opportunity to demonstrate the technology in glance.
Hybrid Water Heating Systems combine revolutionary new Sun Bandit® AC micro-grid technology with a Sun Bandit® hybrid water heater to provide a renewable energy solution that offers unrivaled functionality and dependability while incurring far less installation, equipment and maintenance costs than any other solar water heating system on the market. This hybrid system is uniquely designed so that it does not require net metering or grid-tie connection allowing it to operate independently from the main electrical grid and provide free hot water even during a power outage. With no fluids and mechanical components to maintain or wear out, it gives more people in more places the freedom to choose a simple, clean, quiet and reliable renewable energy solution that uses the free energy of the sun to heat water, reduce utility costs, and increase energy independence.
SBES Kit
SBES Kit
(Basic 2 Module package, mounting and racking included).
A (1) Sun Bandit Hybrid Water Heater of your choice including Mix Valve and Temperature Gauge
B (1) Sun Bandit AC MicroGrid Inverter
C (2) Solar Modules
D (4) Zilla Zip Flashing Assemblies with Lfoot and Mounting Hardware
E (2) Zilla Quad Combo rails
F (4) End Clip Assemblies and
(2) Zilla Top Clip Assemblies
G (4) Wire Management Clips
H (1) Zilla PVC Electrical Flashing with Junction Box
I (1) Monitor
J (1) Sun Bandit AC MicroGrid Disconnect
Note:SBES80E100 shown, additional hardware including top clip assemblies, splice bars, AC MicroGrid Inverters and Monitors will be provided to match the system you select.
SB Series 1200-B and 2400-B (Kit)
Included
Note not included
SB Series 1200-B
SB Series 2400-B
Sun Bandit® Solar Hybrid Water Heater
Sun Bandit® Mix Valve
Sun Bandit® Power Pack
Solar PV Modules
Solar PV Mounting System
AC Discount
30 Amp Discount
15 Amp Fuse
5 Circuit Ground Bus Bar
30 Amp Discount
20 Amp Fuse
5 Circuit Ground Bus Bar
AC Discount
30 Amp Discount
15 Amp Fuse
5 Circuit Ground Bus Bar
30 Amp Discount
20 Amp Fuse
5 Circuit Ground Bus Bar
Balance of System
Junction Box
#6 Bar Copper Wire
2#10 Copper wire maximum 100′ with
Equipment Ground
Junction Box
#6 Bar Copper Wire
2#10 Copper wire maximum 100′ with
Equipment Ground
Specifications |
SB1200-B |
Number of Inverters / DC Input Channels |
1 / 4 |
Number of Modules per Channel |
1 |
Number of Modules per Circuit |
1, 2, 3 or 4 |
DC Input (per Channel) |
Data |
Recommended |
220 W – 350 W |
Operating |
15 V – 58 V |
Peak Power Performance Range |
30 V – 58 V |
Maximum |
58 V / 9 A |
Minimum Starting Voltage |
20 V |
AC Output (per Inverter) |
Data |
Maximum |
1150 W / 960 W |
Maximum Output Current |
9.5A |
Nominal |
20 V – 240 V, Single-Phase |
Nominal Frequency |
50 Hz – 60 Hz |
Load Resistance Range |
12 ohm – 58 ohm |
E_ciency |
Data |
Peak |
96% / 99% |
Mechanical Data |
|
Ambient Temperature Range |
-40° F to +149° F / -40° C to +65° C |
Internal Operating Temperature Range |
-40° F to +190° F / -40° C to +88° C |
Dimensions w/o mounting bracket (L x H x W) |
12.5”x 9.5” x 2.3” / 32 cm x 24 cm x |
Weight |
14.25 |
Cooling / Enclosure |
Natural Convection, No Fan / Potted |
DC / AC Wire, Connectors |
42” |
Features and Compliance |
Data |
Safety and EMC Compliance |
UL1741 and IEEE1547 (E113426), CSA |
Compatibility |
60-Cell, 72-Cell and Thin |
DC Ground Fault |
Built-In |
Standard Warranty |
6 Years |
Enclosure |
Outdoor – NEMA 6 / Transformer |
Specifications |
SB2400-B |
Number of Inverters / DC Input Channels |
2 / 8 |
Number of Modules per Channel |
1 |
Number of Modules per Circuit |
5, 6, 7 or 8 |
DC Input (per Channel) |
Data |
Recommended PV Module Power |
220 W – 350 W |
Operating Input DC Voltage Range |
15 V – 58 V |
Peak Power Performance Range |
30 V – 58 V |
Maximum Input DC Voltage / Current |
58 V / 9 A |
Minimum Starting Voltage |
20 V |
AC Output (per Inverter) |
Data |
Maximum Output Power / Rated Output |
1150 W / 960 |
Maximum Output Current |
8A |
Nominal Operating AC Output Voltage |
20 V – 240 V, Single-Phase |
Nominal Frequency |
50 Hz – 60 |
Load Resistance Range |
9 ohm – 23 |
E_ciency |
Data |
Peak E_ciency/ MPPT Tracking |
96% / 99% |
Mechanical Data |
|
Ambient Temperature |
-40° F to |
Internal Operating Temperature Range |
-40° F to |
Dimensions |
12.5”x 9.5” |
Weight |
14.25 lbs / 6.5 kg |
Cooling / Enclosure |
Natural Convection, No Fan / Potted |
DC / AC Wire, Connectors |
42” CH 1 & 4, |
Features and Compliance |
Data |
Safety and EMC Compliance |
UL1741 and IEEE1547 (E113426), CSA 107.1, FCC Part 15 Class A |
Compatibility |
60-Cell, 72-Cell and |
DC Ground Fault Detector Interrupter (GFDI) |
Built-In |
Standard Warranty |
6 Years |
Enclosure Environmental Rating/ Safety |
Outdoor – NEMA 6 / Transformer Isolated Circuits |
The most important quality of a solar hot water system is the ability to provide a consistent supply of solar heated hot water. Consistently meeting the hot water demand is what saves customers money on their bill and reduces peak utility demand. The old gold standard of peak collector efficiency plays only a small part in the overall ability of the system to meet demand and should be considered as antiquated as traditional solar thermal technology.
The Green Notions Solar Water Heaters manufactured by the Sun Bandit® Hybrid Energy System proves that overall solar hot water efficiency should be defined by simplicity, reliability, and consistency rather than the potential for excess collector output on the hottest days of the year.
Performance Data based on TMY3 data for Minneapolis, MN with collectors at a 23 degree tilt facing due south. Performance based on Sun Bandit® 300 and a 4×10 flat plate collector.
Performance Data based on TMY3 data for San Diego, CA with collectors at a 23 degree tilt facing due south. Performance based on Sun Bandit® 200 and a 4×8 flat plate collector.
Installation Guide
Our new Hybrid Water Heaters are an easy and affordable way to increase the value of your homes with no long term contracts required. See Step 1&2 below for easy installations:
STEP 1: Install Sun Bandit Hybrid Water Heater
STEP 2: Add Solar Electric Panel Kits
Installation Tips
Read and review all manuals and diagrams prior to installation.
AC Micro-Grid Inverter Installation
✓ DOUBLE CHECK INVERTER MASTER AND SUBORDINATE CONFIGURATION
Micro-Grid Inverters can only be installed with one of the following circuit configurations:
> One (1) Master for use with Two (2) solar PV Panels
> One (1) Master + One (1) Subordinate for use with Four (4) solar PV Panels
NOTE: ANY OTHER CONFIGURATIONS WILL CAUSE DAMAGE AND RESULT IN FAILURE OF THE SYSTEM
✓ MAKE CONNECTION FROM AC MICRO-GRID INVERTER(S) TO WHIP CONNECTION LAST
✓ TREAT INVERTERS AS “LIVE” AS SOON AS PANELS ARE CONNECTED
Inverters are not waiting for grid connection
Solar Hybrid Water Heater Installation
✓ NEVER ENERGIZE A DRY ELEMENT
The water heater must be correctly plumbed and completely filled before energizing any element or burner
✓ INSTALLER MUST BOND THE NEUTRAL (CONNECT NEUTRAL TO GROUND)
Typically done in AC disconnect
✓ CHECK ALL ELECTRICAL CONNECTIONS TO ENSURE THEY ARE TIGHT AND SECURE
✓ RESISTANCE FROM ROOF THROUGH AC MICRO-GRID ELEMENTS SHOULD BE
APPROXIMATELY 19.2 OHMS
✓ SET EACH AC MICRO-GRID ELEMENT THERMOSTAT TO “VERY HOT”
The grid-tied backup thermostat is pre-set from the factory for optimum performance and does not need to be adjusted
✓ WITH POWER DISCONNECTED, MAKE SURE ALL THERMOSTAT AND ELEMENT TERMINALCONNECTIONS ARE TIGHT AND SECURE